ProMinent marka ürünler Özhat tarafından Türkiyeye paralel ithalat yöntemi ile ithal edilmekte ve siz değerli müşterilerimize en hızlı şekilde teslim edilmektedir ProMinent ürünlerinden websitemizde ürün numarası yer almasa bile teklif isteyiniz ; en kısa sürede teklifimiz tarafınıza ulaştırırılacaktır
YALNIZCA ORİJİNAL VE YENİ ÜRÜN SATIŞI YAPMAKTAYIZ
Özhat ProMinent Markasının yetkili distribütörü veya temsilcisi değildir.
Firmamızın internet sitesinde ve katalogta gösterilen tüm markaların yetkili distribütör veya üretici temsilcisi olmayıp, bu sitede gösterilen Özel marka adları ve ticari markalar ilgili sahiplerinin mülkiyetindedir.
Pressure holding/overflow valve for mounting directly on the pump dosing head with the functions፦ pressure holding valve, opening pressure approx. 1.5 bar at free outlet, or pre-pressure on the suction side (black rotary knob) - overflow valve, opening pressure approx. 6, 10 or 16 bar* - intake aid when back pressure is pending - Relieving pressure of the pressure line, e.g. during service work - operation via rotary knobs with automatic reset Material: PVDF seals: FPM and EPDM (included) Type: size III Opening pressure: 10 bar* (overflow function)
* The overflow opening pressure given here is the pressure at which the valve starts to open. Depending on the type of pump, the pressure may be 50% higher until fully opened. Pressure retaining valves are not absolutely tight shut-off devices.
Applikationen sind z.B. Anwendungen im Trinkwasser sowie Schwimmbad
Messgröße: Ozon (O3)
Messbereich: 0,02...2,0 mg/l
Referenzmethode: DPD4 pH-Bereich: 4,0…11,0
Temperatur: 5...40°C max.
Druck: 1,0 bar Anströmung: 30…60 l/h (im Bypass, offener Auslass des Messwassers)
Ausgangssignal: 4…20 mA ~ Messbereich temperaturkompensiert, unkalibriert,keine galvanische
Trennung Sensorarmatur: DGM oder DLG III Messprinzip: amperometrisch, 2 Elektroden, membranbedeckt
Installation im Bypass zur Prozesswasserleitung
Verbindung zum Regler über Steuerleitung LiYY 2x0,25 qmm Bestellnummer: 725122 (ist Meterware) (Messleitung nicht im Lieferumfang enthalten)
Hinweis: **************** Für die Installation in den Durchlaufgeber DLG III ist ein Montageset Bestellnummer 815079 erforderlich. (nicht im Lieferumfang enthalten)
Herkunftsland: DE
pH sensor for use in aqueous polluted media that
contains solids, as well as media with low conductivity.
Applications include waste water, cooling water, process water,
chemical processes and papermaking.
pH range: 1-12
Temperature: 0... 80°C
max. pressure: 6.0 bar
Conductivity: min 50 μS/cm
Screw-in thread: PG 13.5
Electrical connection: SN6 (S8)
Sensor shaft diameter: 12 mm
Installation length: 120 mm
Diaphragm: Dirt-repellent
PTFE ring diaphragm
Electrolyte: Potassium chloride-containing gel
with salt reserve
Note:
***********
For precise measurements, regular calibration and
Adjustment with ProMinent quality buffer solutions recommended!
pH sensor for use in aqueous polluted media that
contain a high solids content.
Applications include waste water, industrial water, process chemicals,
emulsions, suspensions and protein-containing media.
pH range: 1-12
Temperature: 0... 100°C
max. pressure: 16.0 bar @ 25°C, 6.0 bar @ 100°C
Conductivity: min 500 μS/cm
Screw-in thread: PG 13.5
Electrical connection: SN6 (S8)
Sensor shaft diameter: 12 mm
Installation length: 120 mm
Diaphragm: annular gap without diaphragm
Electrolyte: polymer containing potassium chloride
pH electrode PHEF-012-SE
Flat membrane pH sensor for use in aqueous hydrofluoric acid containing media that may contain abrasive solids. Applications include hydrogenic-containing applications in wastewater in the chip industry, in electroplating applications or air washers.
pH range: 0-12
Temperature: 0... 50°C
max. pressure: 7.0 bar
Conductivity: min 150 μS/cm
Threaded thread: PG 13.5
Electrical connection: SN6 (S8)
Diameter of sensor shaft: 12 mm
Installation length: 120 mm
Diaphragm: HDPE annular diaphragm flat (Double Junction)
Electrolyte: Gel containing potassium chloride
for use in aqueous contaminated media
which contain solids, and media with low conductivity.
Applications include wastewater, cooling water, process water,
chemical processes and paper making.
ORP electrode: platinum
Temperature: 0... 80°C
max. pressure: 6.0 bar
conductivity: min 50 µS/cm
Screw-in thread: PG 13.5
Electrical connection: SN6 (S8)
Sensor shaft diameter: 12 mm
Installation length: 120 mm
Diaphragm: Dirt-repellent
PTFE ring diaphragm
Electrolyte: gel containing potassium chloride
with salt stock
Note:
***********
For precise measurements, a regular validation of the sensor is required
recommended with ProMinent quality buffer solutions!